SP Top White

SP Top White

WTA-compliant restoration plaster for masonry with moisture and salt loads

This product is not available to buy online. Please contact us for pricing and more information.

€ 76.25 EUR
INCL. VAT
Every effort has been made to ensure the accuracy of our digital colours and textures however due to limitations with technology, we strongly advise purchasing sample products for testing in situ prior to the full order being placed.
All prices specified on our website include VAT. Contact our team for bulk pricing and trade discounts.
No items found.

Delivery Information

Unless otherwise specified all products within Ireland should be delivered within 2-3 working days. Please contact us for delivery options outside of Ireland or if you wish to ship to Northern Ireland.

Our stock is primarily shipped by Fastway or via the pallet network depending on the total weight of the order. The delivery method will be automatically assigned and priced at checkout. All delivery prices include VAT.

Main Purpose

Coverage

Field of application

For use indoors and outdoors
  • Repair, renovation and restoration of wall surfaces and masonry subjected to moisture and salt loads
  • Internal wall surfaces in cellars, old buildings and facades
  • Can be used in combination with SP Levell in areas exposed to high levels of harmful salts
  • Can be applied in a single layer as an undercoat or finishing coat

Properties

  • High sulphate resistance and low active alkali content (SR/NA)
  • Enables water vapour diffusion
  • Single-layer application thickness up to 30 mm
  • Machine workable

Product specifications

Reaction to fireClass A1

External surveillanceGG Cert + WTA

Maximum grain size1.25 mm
Aggregate as per DIN EN 13139

Capillary water absorption w24> 0.3 kg/m²

Porosity> 50 vol.%

Layer thicknessSingle layer 10 - 30 mm, two layers up to 40 mm

Bulk densityApprox. 0.9 kg/dm³

Water requirementApprox. 5.8 l/20 kg

Water vapour permeabilityµ ≤ 15

Water penetration depthAfter 24 h < 5 mm

Compressive strength classCS II (1.5 - 5.0 N/mm²)

The stated values represent typical product characteristics and are not to be construed as binding product specifications.

Preparation

Substrate requirements

  • Clean, dust-free and capable of supporting a load.

Preparations

  • Remove render, paint layers and coatings at least 80 cm above the damaged area.
  • Chase out friable joints to a depth of at least 2 cm.
  • Pre-wet absorbent substrates so that they are slightly damp.
  • Substrate: absorbent
  • Apply SP Prep or SP Prep rapid as a bonding layer in net form (covering area 50-70%) with max. 5 mm layer thickness.
  • Alternative: apply SP Top White as a scratch coat (contact layer).
  • Substrate: weakly absorbent
  • Apply SP Prep or SP Prep rapid at full coverage (100%) with max. 5 mm layer thickness.
  • Alternative: apply SP Top White as a scratch coat (contact layer).
  • Substrate: mineral waterproofing slurry
  • Apply SP Prep as a full-coverage bonding layer on the last slurry layer wet-on-wet.

Application

Application temperature: min. 5 °C max. 30 °C
Mortar cover / Filling knife / Trowel application / Application by spraying
  • Contact layer
  • Apply the product using a suitable tool.
  • One-layer
  • Apply product using a suitable tool or machine.
  • Two-layer
  • Roughen the first layer with a render comb.
  • Apply second layer once sufficiently dry.
  • Alternatively, apply the total layer thickness in 2 coats, wet on wet, embedding reinforcement fabric (Tex 6.5/100).
  • Ensure that fabric sheets overlap by at least 10 cm.
  • Level off surface with a long float.
  • Finish the surface once set.
  • Prepare the surface for subsequent layers with a grated scraper after sufficient setting.
  • Pre-wet hydrophobic surfaces with detensioned water so that they are slightly damp before applying further render coats.

Application instructions

  • Once it has hardened, mortar must not be made workable again by adding either water or more wet mortar.
  • On critical substrates (highly uneven, fissured, mixed masonry) we recommend incorporating the reinforcement fabric in the upper third of the restoration render.
  • Apply additional diagonal reinforcement to the edges of building openings.
  • Protect wet mortar surfaces against frost, rain and drying out too quickly for at least 4 days.
  • At larger coating thicknesses of 10 - 30 mm, it is recommended to apply the mortar "wet on wet" in the render layer.
  • Work can continue on scraped surfaces can after 24-48 hours.
  • Work can continue on smoothed surfaces after min. 14 days.
  • Hairline/shrinkage cracks are safe and are not cause for complaint as they do not impair the properties of the mortar.
  • To ensure that the renovation is successful, the relevant drying conditions according to WTA Code of Practice 2-9-20/D must be met.
  • Please contact Remmers Technical Service (phone +49 5432 83900) before applying with machine processing.
  • When processing in machines, the product-specific data, such as strength, air void content, etc. might change.

Working tools / cleaning

Mortar cover / Filling knife / Trowel application / Application by spraying
  • Mixing tool, trowel, smoothing trowel, aluminium float, render comb, sponge float
  • Clean tools with water while the material is still fresh.

Storage / shelf life

Protect form moisture
Shelf-life 12 months
  • If stored in an unopened container and in a dry place, the product will keep for approx. 12 months.

Usage

  • Approx. 8.8 kg/m²/cm layer thickness
  • Apply to a large enough trial area to determine the precise amount required.